SAMPLE EVALUATION CHECKLIST

Smart Lock Sample Evaluation Checklist

Evaluate a smart-lock sample as the exact model and configuration being proposed, not only by its appearance or a single successful unlock. Door fit, installation, included access methods, App or account setup where applicable, packaging, documentation and the after-sales process can all affect commercial suitability. Adapt each check to the approved configuration, market, sales channel and representative door. Record failed, conditional and not-applicable items before confirming the final mass-order configuration.

Published: SUPTER
SUPTER smart lock range used for sample evaluation planning
Sample approval in one sentence

A sample should be evaluated against the intended market, door condition, approved configuration, sales channel and after-sales workflow before a mass-order configuration is confirmed.

Confirm the Exact Sample Being Evaluated

Identify the exact sample: model, configuration, finish, lock body, App or platform where applicable, accessories, packaging, manual, date, reference and approved customization.

Similar-looking samples may use different internal, lock-body, platform or accessory configurations. Keep each result attached to the recorded combination.

Model
Approved configuration
Colour or finish
Lock-body option where applicable
App or platform configuration where applicable
Included accessories
Packaging version
Manual version
Sample date
Sample or project reference
Approved customization

Photograph the relevant labels and included items so the tested configuration remains identifiable.

Prepare the Door and Installation Condition

Record the door material, finished thickness, opening, lock body, frame, strike, openings, clearance and restrictions. Confirm which door represents the project.

A successful fit validates only that combination. Review relevant door variations separately.

Door material and construction
Measured finished thickness
Opening direction
Existing lock body
Frame and strike
Current openings
Panel and handle clearance
Installation restrictions

Inspect the Sample Before Installation

Check the delivered sample and its contents before installation begins:

  • Model, configuration and label match
  • Colour, finish and visible consistency
  • Scratches, dents, gaps or visible damage
  • Front and rear panel condition
  • Handle movement before fitting
  • Buttons, sensors and visible components
  • Accessible cables and connectors without disassembly
  • Lock body and faceplate
  • Screws, spindles and installation accessories
  • Mechanical keys where included
  • Cards or other credentials where included
  • Batteries, battery pack or power accessories where included
  • Packaging protection
  • Manual and accessory list

Review Installation and Mechanical Operation

Installation evaluation should use the representative door and the approved product and lock-body configuration. Where applicable, review:

Fit with the actual door
Front and rear panel alignment
Handle return
Latch and bolt movement
Door closing and latching
Inside and outside operation
Frame and strike alignment
Cable routing
Fixing stability
Emergency or mechanical access where included
Visible finish after installation

Any cutting, drilling or structural change must follow the approved installation plan, be reviewed by a qualified local installer and comply with the door manufacturer’s and project requirements. This checklist does not provide universal drilling measurements.

Test Every Included Access Method

Test only the access methods included in the approved sample. Depending on the model and configuration, these may include fingerprint, password, card, mechanical key, mobile App, face recognition, palm-vein recognition, remote access, temporary credentials or another approved method.

These are evaluation categories, not functions included in every SUPTER model.

Fingerprint where included
Password where included
Card where included
Mechanical key where included
Mobile App where included
Face recognition where included
Palm-vein recognition where included
Remote access where supported
Temporary credentials where supported
Other approved methods

For each included method, review:

  • Enrolment or creation
  • Normal authorized use
  • Deletion or revocation
  • Invalid-attempt handling
  • Repeated normal operation
  • User instructions and administrator recovery

Do not apply universal speed, accuracy or capacity expectations. Record the configured function and result.

Evaluate the App, Account and Gateway Where Applicable

For a configuration that includes an App, account or gateway, review the practical setup and management process:

Approved App download source
Account registration
Region or country selection
Device pairing
Administrator role
User addition and removal
Credential management
Event records where supported
Gateway setup where required
Remote functions where supported
Language display
Notification behaviour
Reset and re-pairing
Device transfer or replacement workflow

Available functions depend on the exact model, platform, configuration, account arrangement and gateway. Confirm the approved setup before the sample test; do not assume universal regional availability, gateway compatibility, cloud service, API access or App branding.

Review Power, Battery and Recovery Behaviour

Use the power arrangement included in the approved sample. Where applicable, evaluate:

Battery installation
Charging or battery-pack connection
Power indication
Low-power warning
Operation after normal battery replacement or charging
Emergency-power method where included
Settings after normal battery replacement
Restart behaviour
Administrator recovery
Reset procedure
Mechanical access where included

Repeat Normal Operations and Simulate Daily Use

Repeat ordinary, non-destructive operations to identify inconsistent behaviour that one successful action may not reveal:

  • Multiple normal unlock and lock cycles
  • Different authorized users
  • Inside and outside operation
  • Normal door closing
  • Repeated handle movement
  • App reconnection where applicable
  • Temporary credentials where applicable
  • Normal battery removal and replacement where appropriate
  • Reset and reconfiguration only when included in the approved evaluation

Use a cycle count suitable for the agreed sample plan rather than presenting one number as universal. Where risk or project scale justifies it, compare more than one sample and record whether the same result is repeated.

Routine sample evaluation is not laboratory certification. Formal endurance testing requires a separately defined method, acceptance standard, equipment and reporting process.

Review Packaging, Labelling and Product Identification

Check whether the sample and its presentation can be identified and supported through the intended channel. Review where provided:

Model name
Colour or configuration label
Carton and inner protection
Accessory list
Serial or batch identification
Barcode or QR code
Brand presentation
Logo position
Product labels
App or platform reference
Country or language requirements
Visible damage after normal transport handling

Check Manuals and Documentation

The manual and support materials should match the approved product and configuration. Where applicable, check that they explain:

  • Installation preparation
  • App setup
  • Account creation
  • User enrolment
  • Included access methods
  • Reset
  • Battery replacement or charging
  • Mechanical access
  • Gateway setup
  • Troubleshooting
  • Model identification
  • Support contact and included accessories

Do not assume one generic manual is sufficient for every model or configuration. Manual review can identify clarity and consistency issues, but it does not by itself establish legal or regulatory compliance.

Define the After-Sales and Replacement Workflow

Before sample approval, confirm how the exact version will be identified and supported:

  • Model and configuration identification
  • Information needed when reporting a problem
  • Useful photos or short videos
  • Reset and troubleshooting boundaries
  • Separate accessory identification
  • Matching replacement parts or units
  • App account or device transfer where applicable
  • Packaging and documentation version tracking
  • Communication with the end user, installer or distributor

The review should identify responsibilities and evidence, not promise unrestricted spare parts, free replacement, fixed service times, local installation or local consumer support in every market.

Record Results Consistently

Use one evaluation record for the exact sample and configuration. Include:

Check item
Expected result
Actual result
Pass
Conditional pass
Fail
Not applicable
Evidence
Reviewer
Date
Action required
Retest result

Use “not applicable” when a function is not included in the approved configuration; do not treat its absence as a failed test.

A conditional pass must state the condition that remains to be confirmed, the responsible party and whether a new check is required before final approval.

Sample Evaluation Record

Adapt this record to the approved configuration and protect credentials and personal data.

Evaluation AreaWhat to CheckEvidence to RecordResult OptionsConfiguration-Dependent?
Sample identityModel, configuration, finish and version.Labels, reference and date.Pass / conditional / failYes
Physical conditionPanels, finish, handle and damage.Photos and notes.Pass / conditional / failYes
Door and lock-body fitOpenings, clearance and alignment.Measurements and installed views.Pass / conditional / failDoor-dependent
Mechanical operationHandle, latch, bolt and closing.Observed result.Pass / conditional / failYes
Access methodsEnrolment, use, deletion and recovery.Record by method.Pass / conditional / fail / N/AYes
App and accountsRegistration, pairing, roles and users.Notes without credentials.Pass / conditional / fail / N/APlatform-dependent
Gateway and remote useApproved setup and functions.Configuration and result.Pass / conditional / fail / N/APlatform-dependent
Power and recoveryIndication, replacement, reset and recovery.Condition and result.Pass / conditional / fail / N/AYes
Packaging and labelsProtection, identification and accessories.Approved or redacted photos.Pass / conditional / failChannel-dependent
DocumentationCorrect version, setup and troubleshooting.Version and notes.Pass / conditional / failYes
After-sales workflowEvidence, responsibilities and replacement.Process and actions.Pass / conditional / failProject-dependent
Final approvalOpen items resolved or recorded.Review and retest references.Approve / holdYes

Common Sample-Evaluation Mistakes

Avoid these incomplete conclusions:

  • Testing appearance only
  • Not recording the configuration
  • Using a non-representative door
  • Testing one access method
  • Assuming connected functions match across versions
  • Ignoring reset and recovery
  • Overlooking packaging or documents
  • Not recording accessories
  • Approving branding before product fit
  • Relying on one operation
  • Treating a sample as certification or production proof
  • Not recording conditional retests

What to Send When Reporting a Sample Issue

Provide enough evidence to identify the sample and reproduce the condition without disclosing unnecessary private information:

Model
Configuration
Sample reference
Clear issue description
When the issue occurs
Photographs
Short video where useful
Door and installation information
App, platform and account context where relevant
Gateway information where relevant
Power or battery condition
Exact error message
Steps already attempted
Whether reset was performed
Packaging or accessory issue
Requested next action

How SUPTER Supports Sample Evaluation

SUPTER is a China-based smart lock OEM and ODM partner. Within the approved project scope, SUPTER can organize:

Market-based product selection
Configuration review
Door-information review
Sample preparation
Branding and packaging planning
Manual and documentation preparation
Production and supply coordination
Long-term supply planning

SUPTER’s support does not replace approval by a local installer, laboratory testing, regulatory review or confirmation of door compatibility, and it does not constitute universal approval of the product.

Final Sample-Approval Framework

Use one review sequence:

  1. 01

    Record the sample

    Identify configuration and included items.

  2. 02

    Confirm the door

    Document conditions and restrictions.

  3. 03

    Test included functions

    Review mechanical and electronic methods.

  4. 04

    Review connected functions

    Check App, accounts and gateway where applicable.

  5. 05

    Review the complete product offer

    Review packaging, labels, manuals and accessories.

  6. 06

    Classify results

    Record failed, conditional and N/A items.

  7. 07

    Retest corrections

    Repeat checks and attach evidence.

  8. 08

    Confirm the order

    Finalize after completing the record.

A documented evaluation supports the decision without guaranteeing every door, environment or future unit.

Frequently Asked Questions

Is one successful unlock enough to approve a sample?

No. Review the configuration, door, included functions, repeatability, documentation, packaging and support process.

Should every possible function be tested?

Test every included function. Mark excluded functions as not applicable.

Can one sample confirm compatibility for an entire project?

Only when relevant door conditions are equivalent. Review representative variations separately.

What should be tested in the App?

Where applicable, review registration, pairing, roles, users, credentials, records, remote functions, reset and transfer.

What is a conditional pass?

It records a condition that must be confirmed, corrected or retested before approval.

When should branding and packaging be approved?